Section 7 Diagnostics
7-5
REFRIGERATOR SENSING BULB
LOCATION
All reach-in refrigerators must have the
sensing bulb installed in the evaporator coil,
regardless of the original thermostat bulb
location. Failure to do so will cause the
evaporator coil to frost up.
Angle the cap tube as you insert the sensing
bulb. Insert the sensing bulb exactly 6” into
the evaporator coil. When replacing a
thermostat, be sure to seal the hole in the top
of the cabinet through which the sensing bulb
is inserted.
FREEZER SENSING BULB
LOCATION
All reach-in freezers must have the cap tube
mounted without coils or kinks, to sense the
air temperature entering the evaporator coil.
Figure 7-1: Sensing Bulb Location
EVAPORATOR
DETAIL “A”
CAP TUBE
FINS
CAP TUBE SHOULD NOT TOUCH
EVAPORATOR TUBING
NOTE: PINCH FINS AROUND
CAP TUBE AND RTV AROUND
OUTER EDGE OF CAP TUBE
CAP TUBE
FINS
DETAIL “B”
12 3/4” (RS3)
7 1/2” (RS2)
5 3/4” (RS1)
SV1425
8” (R1, 2, 3/RS1, 2, 3)